Liquid cooling solutions for AI data centers in India.
We supply, integrate, and support the components that move AI workloads from
air-cooled limits to 50–130 kW per rack — dielectric fluids,
CDUs, manifolds, rear-door heat exchangers, and immersion tanks from the world's
critical-cooling vendors.
A single H100 draws ~700 W. A Blackwell B200 draws ~1,200 W. Pack eight per
server, eight servers per rack, and the math breaks the air-cooled envelope.
Liquid is no longer a preference — it's the only option that scales.
Air cooling
PRACTICAL CEILING
8–15kW / rack
Hot-aisle/cold-aisle, in-row CRAC, raised floor. Works for general-purpose
compute. Fails the moment you try to deploy modern GPU servers at density.
Hot-spot formation above 12 kW
Throttling under sustained training load
PUE typically 1.5–1.8 in tropical climates
No path to H100 / Blackwell density
Liquid cooling
PROVEN OPERATING RANGE
50–130kW / rack
Direct-to-chip cold plates, rear-door heat exchangers, or full immersion.
Heat removed at the source, water year-round, dramatically lower energy
overhead.
Sustained turbo on H100 / Blackwell
Up to 95% of heat captured in liquid
PUE 1.05–1.15 even in Chennai climate
Headroom for next-gen accelerators
02 / Solutions
Three product lanes. One integrated supply chain.
We carry a curated set of vendors across the liquid-cooling stack, sized to
what Indian operators actually deploy — not catalogues we can't service.
— 01
Dielectric coolant fluids
Single-phase and two-phase fluids engineered for direct contact with electronics.
Long-life, low-GWP, non-conductive.
— Authorised & channel partners across the stack —
Shell
Castrol
Submer
GRC
Motivair
CoolIT
Vertiv
Schneider
Stulz
03 / Why Hydroniq
Specialised. Local. End-to-end.
We don't sell servers, we don't sell power, we don't sell racks. We do one
thing — get heat out of your AI hall — and we do it on the ground in South India.
/01
South India focus
Chennai, Bengaluru, Hyderabad, Vizag, Kochi. We know the climate, the power
situation, the contractors, the customs lanes. Site visits inside 24 hours.
/02
Technical depth, not catalog sales
Thermal load calculations, CDU sizing, fluid compatibility, manifold flow
balancing. Our engineers have deployed liquid loops; they don't read off a spec sheet.
/03
End-to-end deployment
Procurement, customs, on-site commissioning, fluid filling, leak testing,
monitoring integration, and post-go-live SLA support. One partner, one chain of custody.
— Ready when you are —
Planning an AI hall? Let's run the numbers.
Send us your rack count, target density, and timeline. We'll come back inside
48 hours with a sized solution and a delivered cost.